High quality electrochemical cells and systems

Micro Flow Cell

Download product sheet

Applications

  • Small lab evaluations of electrochemical processes when
    minimal flows and chemical use are requirements
  • Process studies with expensive chemicals
  • Screening tests on different chemicals, electrodes and membranes
  • Evaluation of different fuel cell- and redox concepts

Features

  • Possibility of 4 different electrolyte flows
  • Leak-proof construction
  • Gas diffusion electrodes can be installed
  • Set of electrodes (Pb, Ni and DSA-CI2) supplied in addition to the cell electrodes (SS and DSA-O2 pH<2)
  • Designed to allow for internal heating / cooling
  • Small internal cell volume
  • Turbulent promoter for improves mass transfer
  • Full laboratory package available with cell as option 

From lab, pilot to production – Electro Cell is the “One-Stop-Shopping-Place”

Expertly designed and engineered flow cells are available for applications including chloralkali and synthesis of a wide range of inorganic and organic chemicals. These modular membrane cells have found application world-wide! Start with a laboratory unit as small as 0.01 m2 (Electro MP Cell) or 0.04 m2 (ElectroSynCell) and expand to a pilot scale module, and then to the production plant size by adding on modules, or installing the Electro Prod Cell, especially designed for production. Injection moulded cell parts are available in a wide range of inert materials. Electrodes can be of DSA®, Pt on Ti, PbO2 on Ti, graphite and many others. Further advantages; leakproof, uniform hydrodynamics and current distribution, and narrow inter-electrode gap. 

Technical Data

Electrolyte Flow Data
Max number of separate flows (compartments) 4 Pipe connections, thread

1/8 NPT

Max electrolyte flow per frame (l/min) 0.18-1.5 Electrode materials Pb, PbO2, Ti, DSA for O2, DSA for CI2, PbO2 on Ti, Pt on Ti, Ir on Ti, SS, Fe, Zn, Ni, Cu, Sn, Graphite. Others on request
Electrolyte volume per cell (litre) 0.01 Frames and other plastic components PTFE (Teflon) as standard PVDF, PP, Halar and others on request
Flow rate in each cell (m/sec) 0.05-0.4 Membranes Ion-selective (Nafion 423 as standard). Others on request
Max working temp: Dependent on choice of frame material Gaskets Viton (standard). On request: EPDM, Chloroprene, Silicone, Nitrile or Butyle.
Hardware Stainless Steel
Main Dimensions
Electrode area, m2 0.001
Height, mm 120
Width, mm 70
Length, mm

33 (2-comp), 38  (3-comp)

Pipe connections, outer diam 1/4"

Characteristics of cells

Electro MP Cell ElectroSynCell ElectroProdCell
Electrode area (min): 0.01 m2 0.04 m2 0.4 m2
(max) 0.2 m2/module 1.04 m2/module 16.0 m2/module
Current density (max): 4 kA/m2 4 kA/m2 4 kA/m2
Interelectrode gap: 6-12 mm 5 mm 0.5-4 mm
Electrolyte flow, per cell: 1-5 l/min 5-15 l/min 10-30 l/min
Flow Rate in each cell: 0.03-0.3 m/s 0.2-0.6 m/s 0.15-0.45 m/s